Electrical and Environmental Specifications

The print engine, which includes the DocuSP Controller, requires:

Frequency

50/60 hz

Voltage

200 - 240 VAC

Amps

Dedicated 30 amps. The outlets/circuits can not be shared with any other devices or equipment. Optional 50 amp Adapter Box and 30A Extension Box with appropriate circuit breakers are available.

Receptacle NEMA Part Number

14-30 R

Temperature and Humidity

Recommended 68 degrees F to 76 degrees F

15% relative humidty (minimum) to 85% relative humidity (maximum)

Heat Emission

Approximately 4,940 BTU/hour (standby) and 37,476 BTU/hour (running)

Power Consumption

Approximately 1.446 kw (standby) and 10.970 kw (running). For information on power consumption, see Power Saver Mode.

 

Energy Star Logo

As an ENERGY STAR® partner, Xerox Corporation has determined that
the Xerox Nuvera Copier/Printer meets the ENERGY STAR® guidelines for energy efficiency.