Electrical and Environmental Specifications
The print engine, which includes the DocuSP Controller, requires:
Frequency
50/60 hz
Voltage
200 - 240 VAC
Amps
Dedicated 30 amps. The outlets/circuits can not be shared with any other devices or equipment. Optional 50 amp Adapter Box and 30A Extension Box with appropriate circuit breakers are available.
Receptacle NEMA Part Number
14-30 R
Temperature and Humidity
Recommended 68 degrees F to 76 degrees F
15% relative humidty (minimum) to 85% relative humidity (maximum)
Heat Emission
Approximately 4,940 BTU/hour (standby) and 37,476 BTU/hour (running)
Power Consumption
Approximately 1.446 kw (standby) and 10.970 kw (running). For information on power consumption, see Power Saver Mode.
As an ENERGY STAR® partner, Xerox Corporation has determined that
the Xerox Nuvera Copier/Printer meets the ENERGY STAR® guidelines for energy efficiency.