Skip to main contentClick to view our Accessibility Statement or contact us with accessibility-related questions.

Reseat the Imaging Units

Product support for
Xerox C325 Multifunction Color Printer
Article ID
KB0426927
Published
2025-01-31

 

Instructions

 

Warning: Do not perform this procedure when the printer is copying or printing.

  1. Open Door A and Door B.



  2. Remove the waste toner bottle.



  3. Remove the toner cartridge from the printer.



  4. Do the following to remove the Imaging Kit:

    1. To unlock the Imaging Kit, pull up the lever.



    2. Pull the Imaging Kit out slowly from the printer and take out the Imaging Kit by holding the handles on both sides.

      Note: Refer to the installation instructions included in the Imaging Kit.



  5. Remove and then reinsert the Required Developer unit by lifting them out of the Imaging Kit.

    Caution: Do not expose the photoconductor unit to direct light for more than 10 minutes. Extended exposure to light may cause print quality problems.

    Warning: Do not touch the shiny photoconductor drum under the developer units. Doing so may affect the quality of future print jobs.

  6. Hold the handles of the Imaging Kit and insert it back into the printer.



  7. To lock the Imaging Kit, pull down the lever.



  8. Insert the toner cartridge back into the Imaging Kit.

    Note: Refer to the installation instructions included in the Imaging Kit.



  9. Re-insert the waste toner container back into the printer.



  10. Close Door B and Door A.