Skip to main contentClick to view our Accessibility Statement or contact us with accessibility-related questions.

Remove and Re-install the Fuser Assembly

Product support for
WorkCentre 7425/7428/7435
Article ID
KB0237834
Published
2016-12-13

WARNING: The Fuser Assembly may be very hot and should be handled with care! Use the lifting handles on each end to avoid any contact with hot surfaces during removal or replacement. Avoid any contact with internal parts of the cartridge.

Damage to a work surface may result if a hot Fuser Assembly is removed and positioned on an unprotected surface. Place the assembly on a minimum of 10 sheets of paper.

  1. Power off the machine using the power switch located on the right front side of the machine under the Control Panel.

    Power off the machine using the power switch located on the right front side of the machine under the Control Panel.

  2. Open the Bypass Tray (Paper Tray 5), located on the left side of the printer, by rotating it outward.

    Open the Bypass Tray

  3. Lift up on the release lever on the Top Left Cover A to open the cover.

    Open the Top Left Cover A

  4. Wait at least 40 minutes for the Fuser Assembly to cool.

  5. When the Fuser has cooled, remove the Fuser Assembly by rotating the orange screws (on each side of the assembly) to the left until they are completely loosened.



  6. Grasp the Fuser Assembly by the two handles and pull it straight out of the machine.



  7. Hold the Fuser Assembly by the two handles and then insert it into the machine.



  8. Tighten the two locking screws (rotate to the right).



  9. Close the cover.

  10. Close the Bypass Tray and then power on the machine.