Skip to main contentClick to view our Accessibility Statement or contact us with accessibility-related questions.

Auto Alignment Procedure

Product support for
Xerox Versant 3100 Press, Xerox Versant 4100 Press, Xerox Versant 2100 Press
Article ID
KB0013987
Published
2020-11-03

The Auto Alignment option automatically performs corrective registration, perpendicularity, skew, and magnification adjustments.
Perform the Pre-alignment Procedure before performing the following steps. See the Related Content for additonal information.

  1. From the Stock Library Manager main window, select Profiles.



    The Profiles window opens.



  2. Ensure that the Alignment tab is displayed. Alignment should be first tab displayed after selecting Profilesfrom the Stock Library Manager main window.

  3. Select New or Edit to create a new alignment profile or to edit/modify an existing alignment profile.Either the New Profile Properties or the Edit Profile Properties window opens.



  4. If desired, enter a new name or modify the existing name.

  5. Select the Auto Alignment button.



    The Test Printwindow for Auto Alignmentopens.



  6. Select the appropriate tray and profile name.

  7. Select the Start button.

    • The press runs a test print and perform the automatic adjustments.

    • Once the press completes the test print, the following message displays: Examine the test print. If the print alignment is an improvement, click "OK" to accept the new settings. If the alignment isn't an improvement, click "Cancel" to revert to the original settings.

    • Before selecting either OK or Cancel, continue to the next step.

  8. Review the test print output and choose one of the following:

    • The test print output is an improvement and is acceptable, perform the following:

      1. Select OK to close the Auto Alignment - Confirmationwindow.

      2. Select OK to save and close the New/Edit Profiles Properties window.

      3. Select Close to exit Profiles and return to the Stock Library Manager main window.

    • The test print output is not an improvement and is not acceptable. Select Cancel to close the Auto Alignment - Confirmation window and perform the procedure for Using Manual Test Print for an Alignment Profile. See the Related Content for additonal information.