Skip to main contentClick to view our Accessibility Statement or contact us with accessibility-related questions.

Environmental Specifications

Product support for
Xerox Versant 180 Press, Xerox Versant 280 Press, Xerox Versant 80 Press
Article ID
KB0013977
Published
2020-11-02

The temperature and relative humidity of the room where the press is located must be within the minimum and maximum allowable temperature and relative humidity limits for the press system to operate correctly.

Ambient temperature

  • The operating temperature range is 10° to 32° Celsius (50° F to 90° F)

  • Ambient temperature for optimal image quality and paper handling performance is achieved at 20–24° C (68–76° F)

    Note: The press can operate outside of this range, but the performance cannot be guaranteed.

Relative humidity

  • The required humidity range is 15 % to 85% (relative humidity) - (RH) J zone (Dew condensation is inhibited)

  • Relative humidity for optimal image quality and paper handling performance is achieved at 45% RH

    Note: The press can operate outside of this range, but the performance cannot be guaranteed.

Altitude

The press functions at the elevation of 0 to 2,500 meters (0 to 8,200 feet)