Replace the Suction Filter

Product support for
Xerox Versant 3100 Press, Xerox Versant 4100 Press, Xerox Versant 2100 Press
Article ID
KB0013826
Published
2020-11-03

You will need the T10 Torx driver tool for this procedure.

After you replace the filter, you will need to contact the system administrator who will log into administrator mode and reset the HFSI counter for this CRU to zero (0).

CAUTION:
Make sure the press is powered off before performing this procedure.

  1. At the back of the press, locate the Suction filter cover on the lower panel.

  2. Use the Torx driver to remove the screw on the right side of the cover by turning the screw counterclockwise.

  3. Pull out and remove the Suction filter cover.

  4. Grasp the handle of the filter box and pull straight out.


  5. Remove the Suction filter out of the box.

  6. Place the new Suction filter into the box and push the tray back in until it stops and is flush with the press.

  7. Place the cover back onto the filter box area.

    1. Make sure to first insert the left two tabs of the cover into the left side of the box area.

    2. Then push the entire cover flush to the press.

  8. Insert the Torx driver with the screw attached into the cover and turn clockwise to tighten.

  9. Either log in as the administrator or ask the administrator to perform the following steps to reset the HFSI count to zero (0), which indicates a new filter has been installed.

    1. At the Control Panel, press the Tools button.

    2. From the screen that displays, select the Tools icon.

    3. Select System Settings > Common Service Settings > Maintenance.

    4. Use the up/down arrow buttons to access the next Maintenance screens.

      Note: After selecting the icon in following step, there is a 4 second delay before the Technical Key Operator feature displays.

    5. Select the Technical Key Operator (TKO) icon. The Technical Key Operator feature displays.

    6. Log in to the Technical Key Operator mode.

      Important: If you cannot log in as TKO, or do not have the TKO password, call your Customer Service Engineer.

    7. In the Part Number list, select Suction Filter.

    8. Select Reset Current Value. The system resets the HFSI to 0.

  10. Exit administrator mode.

    1. To return to Tools tab, select Close twice. The main Tools screen displays.

    2. Select the Log In / Out button on the Control Panel.

    3. When prompted, select Logout.